We do not classify our products as medical devices. Our products are recommended for laboratory professional use only.

Memmert

Memmert IPP1060ecoplus Peltier-Cooled Incubator

The Memmert IPP1060ecoplus Incubator is designed for laboratories that require precise temperature control with advanced monitoring and programming capabilities at the highest capacity. Using energy-efficient Peltier technology, it enables both heating and cooling within a single system without the need for a compressor.

With its 1060-litre chamber, the IPP1060ecoplus is optimised for applications below ambient temperature and supports large-scale, continuous laboratory workflows. It combines stable temperature performance with advanced control features, making it suitable for research, quality assurance, and regulated environments.

Category: Tag: Brand:

Memmert IPP1060ecoplus Peltier-Cooled Incubator

Key Features of Memmert IPP1060ecoplus

  • Ultra-large 1060-litre chamber for industrial-scale and continuous workflows
  • Peltier technology for precise heating and cooling in one system
  • Highly energy-efficient operation without compressor
  • Optimised for incubation below ambient temperature
  • Fast heat-up, cool-down, and recovery performance
  • Fan-assisted air circulation for uniform and gentle temperature control
  • TwinDISPLAY control system for intuitive operation and precise settings
  • Advanced programming with multi-step profiles and time control
  • Data logging, USB/Ethernet connectivity, and remote monitoring
  • Quiet, vibration-free operation
  • Environmentally friendly design without refrigerant
  • Low heat emission to surrounding laboratory environment

Applications

The Memmert IPP1060ecoplus incubator is suitable for:

  • Temperature-controlled incubation below ambient conditions
  • Stability and storage applications
  • Microbiology and biological research
  • Pharmaceutical and medical laboratory testing
  • Quality assurance and controlled testing workflows
  • Food analysis and food chemistry

Incubator Series Overview

Series Technology Cooling Capability Airflow Key Advantage Ideal For
IN Electric heating No Natural convection Gentle environment, minimal airflow disturbance Sensitive samples
IF Electric heating No Forced convection (fan) Faster recovery and better temperature uniformity Routine lab work
ICP Compressor cooling + heating Yes (compressor) Forced convection (fan) Wide temperature range, strong cooling performance Environmental testing, variable temperature studies
IPP Peltier heating & cooling Yes (Peltier) Fan-assisted airflow Balanced performance with more control options General lab & research use
IPPeco Peltier heating & cooling Yes (Peltier) Fan-assisted airflow Energy-efficient, precise, quiet operation Routine applications
IPPecoplus Peltier heating & cooling Yes (Peltier) Fan-assisted airflow Advanced control & monitoring Research & regulated labs

Why Choose Memmert Incubators?

Memmert incubators are trusted worldwide for:

  • Precise temperature control
  • Reliable performance in laboratory environments
  • High-quality German engineering
  • Long-term durability and safety

Why Work With Copens Scientific?

  • Genuine Memmert laboratory equipment
  • Expert technical consultation for your applications
  • Reliable after-sales support and assistance
  • Experience supporting laboratories across Malaysia
  • Responsive service for enquiries and quotations

Get Expert Advice or Custom Solutions?

On this page, you’ll find the essential technical details of the Memmert incubator.

If you need further clarification, our customer support team is ready to assist with product selection, specifications, and application suitability.

For customised solutions or special requirements, feel free to contact our technical specialists at info@copens-sci.com

Technical Specification

Temperature

Setting temperature range 0 to +70 °C
Working temperature range without light: from 0 (at least 20 below ambient temperature) to +70°C
Setting accuracy temperature 0.1 °C
Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error

Control technology

ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
Language setting German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function SetpointWAIT the process time does not start until the set temperature is reached
Calibration three freely selectable temperature values
adjustable parameters temperature (Celsius or Fahrenheit), programme time, time zones, summertime/wintertime

Ventilation

Convection forced ventilation by Peltier fan

Communication

Documentation programme stored in case of power failure
Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port

Safety

Temperature control adjustable electronic overtemperature monitor and mechanical temperature limiter
Autodiagnostic system for fault analysis

Heating concept

Peltier energy-saving Peltier heating-/cooling system integrated in the rear (heat pump principle)

Standard equipment

Works calibration certificate for +10 °C, +25 °C and +40 °C
Door inner glass doors
Door fully insulated stainless steel doors with
2-point locking (compression door lock)
Internals 2 stainless steel grid(s), electropolished

Stainless steel interior

Dimensions w(A) x h(B) x d(C): 1040 x 1200 x 850 mm (d less 32 mm for fan - Peltier)
Volume 1060 l
Max. number of internals 14
Max. loading of chamber 200 kg
Max. loading per internal 20 kg

Textured stainless steel casing

Dimensions w(D) x h(E) x d(F): 1224 x 1720 x 1005 mm (d +56mm door handle & +111mm Peltier element)
Installation on lockable castors
Housing rear zinc-plated steel

Electrical data

Voltage
Electrical load
230 V, 50/60 Hz
approx. 1300 W

Ambient conditions

Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
Ambient temperature 16 ºC to 40 ºC
Humidity rh max. 70 %, non-condensing
Altitude of installation max. 2,000 m above sea level
Overvoltage category II
Pollution degree 2

Packing/shipping data

Transport information The appliances must be transported upright
Customs tariff number 8419 8998
Country of origin Federal Republic of Germany
WEEE-Reg.-No. DE 66812464
Dimensions approx incl. carton w x h x d: 1370 x 1970 x 1300 mm
Net weight approx. 248 kg
Gross weight carton approx. 327 kg

Standard units are safety-approved and bear the test marks

CE
EAC Eurasian Conformity
VDE
UL
×