We do not classify our products as medical devices. Our products are recommended for laboratory professional use only.

Memmert

Memmert HCP150 Humidity Chamber

The Memmert HCP150 Humidity Chamber is designed for precise humidity control in applications where reliability and consistency are critical. With its 156-litre chamber, it supports larger sample volumes while maintaining stable environmental conditions.

It is commonly used for accelerated life testing (ALT) and 85/85 testing (85°C / 85% RH), especially in electronics, materials, and product validation processes. These controlled conditions help simulate long-term exposure within a shorter time frame.

Category: Tag: Brand:

Memmert HCP150 Humidity Chamber

Key Features of Memmert HCP150

  • Precise humidity control for reliability testing
  • 156-litre capacity for medium to large sample volumes
  • Stable temperature and humidity conditions for repeatable results
  • Suitable for 85/85 testing and accelerated life testing (ALT)
  • Designed for electronics, materials, and component testing
  • Stainless steel interior for durability
  • Consistent performance in laboratory and industrial environments

Temperature & Humidity Working Range (HCP Series)

Not all climate chambers operate under the same conditions. Factors such as the moisture content of the samples, surrounding ambient conditions, and the required temperature–humidity range all influence the selection of the right chamber.

The HCP series is designed to support a wide range of temperature and humidity combinations. The working range diagram illustrates how these parameters can be adjusted to suit different testing requirements.

Under standard ambient conditions (22 °C ± 3 K and relative humidity below 50%), the chamber can operate continuously within its specified range. Near the boundary limits, condensation may occur depending on the sample load and environmental conditions.

Applications

The Memmert HCP150 humidity chamber is suitable for:

  • Accelerated life testing (ALT) for product durability
  • 85/85 testing (85°C / 85% RH) for electronics reliability
  • Moisture resistance and ageing studies
  • Material and packaging testing under controlled humidity
  • Environmental stress testing for components and assemblies

Why Choose Memmert Equipment?

Memmert systems are known for:

  • Accurate humidity and temperature control
  • Reliable performance in testing environments
  • High-quality German engineering
  • Long-term durability and consistency

Climate Chamber vs Humidity Chamber vs Constant Climate Chamber

Type What It Does Ideal For
Climate Chamber Controls temperature and humidity over a wide operating range (heating + cooling) Environmental simulation, stability testing, pharmaceutical and lab research
Humidity Chamber Focuses on high humidity conditions with temperature support 85/85 testing, accelerated life testing, moisture and electronics reliability testing
Constant Climate Chamber Maintains highly stable temperature and humidity with minimal fluctuation Stability testing, long-term storage, pharmaceutical and ICH-compliant studies

Why Work With Copens Scientific?

  • Genuine Memmert laboratory equipment
  • Expert technical consultation for your applications
  • Reliable after-sales support and assistance
  • Experience supporting laboratories across Malaysia
  • Responsive service for enquiries and quotations

Get Expert Advice or Custom Solutions?

On this page, you’ll find the essential technical details of the Memmert humidity chamber.

If you need further clarification, our customer support team is ready to assist with product selection, specifications, and application suitability.

For customised solutions or special requirements, feel free to contact our technical specialists at info@copens-sci.com

Technical Specification

Temperature

Working-temperature range +7 above ambient temperature up to +90 °C
Setting temperature range +18 to +90 °C
Setting accuracy temperature 0.1 °C
Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error

Humidity

Humidity Control Active microprocessor control for humidifying and dehumidifying (20 – 95 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times. Humidity supply with water (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7; from an external tank) by a self-priming pump; integral bacteria block by generating hot steam, dehumidifying via sterile filter
Setting range active humidity control 20 to 95 % rh and rh-Off
Setting accuracy humidity 0.5 % rh

Control technology

ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
Language setting German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
adjustable parameters temperature (Celsius or Fahrenheit), relative humidity, programme time, time zones, summertime/wintertime
Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function SetpointWAIT the process time does not start until the set temperature is reached
Calibration three freely selectable values each, temperature and humidity

Communication

Interface Ethernet LAN, USB
Documentation programme stored in case of power failure
Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port

Safety

AutoSAFETY additionally integrated over- and undertemperature monitor "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature
Autodiagnostic system integral fault diagnostics for temperature and humidity control
Alarm visual and acoustic

Heating concept

6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation

Standard equipment

Works calibration certificate Works calibration certificate (measuring point chamber centre) at 60 °C with 75 % rh
Door Additional heated inner glass door
Door fully insulated stainless steel door with 2-point locking (compression door lock)
Entry port Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back, centre left
Internals 2 perforated stainless steel shelf/shelves
Standard accessories Water tank including connection hose

Stainless steel interior

Dimensions w(A) x h(B) x d(C): 560 x 700 x 400 mm (d less 35 mm for fan)
Interior W.-St. 1.4301 (ASTM 304)
Volume 156 l
Max. number of internals 10
Max. loading of chamber 120 kg
Max. loading per internal 15 kg

Textured stainless steel casing

Dimensions w(D) x h(E) x d(F): 719 x 1070 x 591 mm (d +56mm door handle)

Electrical data

Voltage
Electrical load
230 V, 50/60 Hz
approx. 1800 W

Ambient conditions

Ambient temperature 10 °C to 30 °C
Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
Humidity rh max. 70 %, non-condensing
Altitude of installation max. 2,000 m above sea level
Overvoltage category II
Pollution degree 2

Packing/shipping data

Transport information The appliances must be transported upright
Customs tariff number 8419 8998
Country of origin Federal Republic of Germany
WEEE-Reg.-No. DE 66812464
Dimensions approx incl. carton w x h x d: 800 x 1250 x 800 mm
Net weight approx. 90 kg
Gross weight carton approx. 116 kg

Standard units are safety-approved and bear the test marks

CE
VDE GS
cMET
EAC
×
×