We do not classify our products as medical devices. Our products are recommended for laboratory professional use only.

Memmert

Memmert CO₂ Incubator ICO105

The Memmert ICO105 CO₂ Incubator is designed to provide an exceptionally stable and contamination-controlled environment for sensitive cell culture applications. With its 108-litre chamber, precision temperature regulation, dual-beam NDIR CO₂ control, and advanced humidity management, the ICO105 delivers highly reproducible cultivation conditions for research, biotechnology, pharmaceutical, IVF, and clinical laboratories.

Its integrated 180°C sterilisation programme, condensation-free chamber design, intuitive touchscreen interface, and modern connectivity help laboratories maintain consistent culture conditions while reducing contamination risks and simplifying daily operation.

Category: Tag: Brand:

Memmert ICO105 CO₂ Incubator

Next Generation CO₂ Incubation

Designed to provide stable and reproducible cultivation conditions with advanced environmental control, contamination protection, and intelligent connectivity for today's life science laboratories.

  • Condensation-free operation
  • Modern connectivity
  • ACT Label Certified
  • Memmert German engineering
Memmert CO2 Incubator

Intelligent Touchscreen Control

Designed for ease of use, the modern interface simplifies monitoring, programming, and data management while keeping critical information clearly visible during operation.

  • Integrated IPS multi-touch display
  • Intuitive user interface
  • Historical data access
  • Device-based programming
  • User authentication
Memmert ICO Display Panel 2026

Memmert myChamber Digital Ecosystem

Connect Memmert ICO to myChamber for smarter laboratory management, improved accessibility, and seamless digital workflow integration.

  • Remote monitoring via smartphone
  • Centralised device management and programming
  • Audit-compliant LIMS integration
  • FDA-compliant documentation

Memmert myChamber 2026

Key Features of Memmert ICO105

  • 108-litre stainless steel chamber for medium-volume cell culture applications
  • Temperature range from ambient +5°C to +50°C
  • Precise dual-beam NDIR CO₂ control from 0–20%
  • Condensation-free operation at 37°C and 95% RH
  • Humidity control from 40–98% RH with optional active humidity regulation
  • Optional oxygen control (1–20% O₂) for hypoxic and anaerobic research
  • Integrated 180°C hot-air sterilisation programme without removing sensors
  • Large 6.86-inch IPS multi-touch display with graphical monitoring
  • USB-C and Ethernet LAN connectivity for data management
  • Dual Pt1000 safety monitoring system with visual and acoustic alarms
  • Smooth stainless steel interior for easy cleaning and reduced contamination risk
  • German-engineered quality for reliable long-term laboratory performance

Applications

The Memmert ICO105 CO₂ Incubator is designed for demanding cell culture applications in research, clinical environments, and pharmaceutical development. It provides precisely controlled temperature, CO₂ concentration, humidity, and optional oxygen regulation to support sensitive biological materials and reproducible cultivation conditions.

Typical applications include:

  • Regenerative medicine and stem cell research
  • Personalised medicine
  • Spheroid research
  • Organoid research
  • Clinical diagnostics
  • CAR T-cell therapy
  • Pharmacology and pharmaceutical development
  • In Vitro Fertilisation (IVF)
  • Cell culture laboratories
  • Biomedical research
  • Clinical research
  • Biotechnology laboratories
  • Academic and university research
  • Any application requiring stable and reproducible environmental conditions for sensitive biological samples

Why Work With Copens Scientific?

  • Genuine Memmert laboratory equipment
  • Expert technical consultation for your applications
  • Reliable after-sales support and assistance
  • Experience supporting laboratories across Malaysia
  • Responsive service for enquiries and quotations

Get Expert Advice or Custom Solutions?

On this page, you’ll find the essential technical details of the Memmert CO₂ Incubator.

If you need further clarification, our customer support team is ready to assist with product selection, specifications, and application suitability.

For customised solutions or special requirements, feel free to contact our technical specialists at info@copens-sci.com

Technical Specification

Range of functions

Calibrate Three freely selectable values: temperature, humidity, and CO2
Interfaces USB-C; Ethernet LAN
Timer Timer - Process time starts immediately when the programme starts; Timer SetpointWAIT - Process time only starts after all setpoint values have been reached; Timer on Event - Process time starts at a defined point in time
Language settings English (default), German, French, Spanish, Portuguese, Chinese, Arabic, Hindi, Polish, Czech, Hungarian, Russian, Italian, Serbian
Appliance functions Date and time (time zones, summer/winter time); Display brightness; DistanceView (1–4 freely selectable parameters, activation time adjustable); Network settings (IP, subnet, DHCP); Language and volume settings (buzzer/key tone); Power failure behaviour; Timer functions
Adjustable parameters Temperature; CO2; Humidity (requires option K7); O2 (requires option T6)
Control unit 6.86" IPS touch display (480 × 1280 pixels) with multi-touch function for graphical display of actual/setpoint values and parameter curves.

O2 (only with T6 option)

Control system Anaerobic O2 control for targeted oxygen reduction via nitrogen inlet. Zirconium oxide sensor with integrated monitoring and error display. Filtered N₂ supply for safe process conditions.
Adjustment precision 0,1 %
O2 - Setting range 1 to 20 %

Temperature

Working temperature range at least 5 °C above room temperature to +50°C
Standard sterilisation programme: 60 minutes at 180 °C (without removing the sensors)
Setting temperature range +20 °C to +50 °C
Setting accuracy 0.1 °C
Spatial temperature variation at + 37 °C +/- 0.3 K
Temporal temperature variation at + 37 °C +/- 0.1 K
Temperature control system Large-area multi-zone multifunctional all-round heating with additional door, seal and rear wall heating

Humidity

Humidification system Passive humidification by means of integrated water tank with condensate return via magnetically guided sealing lip. Humidity limitation by Peltier element. / Active closed-loop humidity control (option K7) with capacitive sensor for precise measurement and complete documentation. Humidification via self-priming micro-dosing pump with hot steam generation, dehumidification via powerful diaphragm pump.
Accuracy 0,5% rh
Setting range 40 to 98 and rh-Off

CO2

Control system Precise CO2 control with dual-beam NDIR technology, integrated monitoring and pressure-compensated measurement. Filtered CO2 supply for high process reliability.
Temporal fluctuation ± 0,2 %
Setting range 0 to 20 %

Safety

Power failure Manual mode / Power failure less than 24 hours: Active process is terminated, parameters remain stored. Power failure longer than 24 hours: Operation continues with previously set parameters. Program mode (power failure >1 hour) / Failure less than 1 hour: Programme continues with remaining runtime. Failure longer than 1 hour: Programme is stopped; query for continuation required
Temperature monitoring Dual Pt1000 sensor, DIN Class A, for mutual monitoring and automatic takeover in the event of a fault
Alarm visual and acoustic

Standard equipment

Standard option Door-open detection | V5
Factory calibration certificate III (Option T6) +37 °C, 5 %CO2, 90 %RH, 10 %O2
Factory calibration certificate II (Option K7) +37 °C, 5 %CO2, 90 RH
Factory calibration certificate I (Standard) +37 °C, 5 %CO2
Additional accessories CO2 connection set, hose with connection coupling and hose clamp; Water tank | B38737; Water tank including connection hose; Stored sterilisation programme: 60 minutes at +180 °C (without removing the sensors)
Door fully insulated stainless steel door with 2-point locking (compression door lock)
Door inner glass door with opening (8 mm Ø) to take gas sample
Internals 1 perforated stainless steel shelf/shelves

Stainless steel interior

Dimensions w (A) x h (B) x d (C): 560 x 480 x 400 mm
Inner cover 37,5 mm
Volume 108 l
Max. number of internals 5
Max. loading of chamber 75 kg
Max. loading per internal 15 kg

Textured stainless steel casing

Dimensions w(D) x h(E) x d(F): : 708 x 683 x 589 mm
Installation 4 adjustable appliance feet

Electrical data

Voltage Electrical load 230 V, 50/60 Hz approx. 1300 W

Ambient conditions

Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
Altitude of installation max. 2,000 m above sea level
Ambient temperature 10 °C to 35 °C
Overvoltage category II
Pollution degree 2

Packing/shipping data

Transport information The appliances must be transported upright
Customs tariff number 8419 8998
Country of origin Federal Republic of Germany
WEEE-Reg.-No. DE 66812464
Dimensions approx incl. carton w x h x d: 825 x 967 x 815 mm
Net weight approx. 70 kg
Gross weight carton approx. 85 kg

Standard units are safety-approved and bear the test marks

CE
×