Key Features of Memmert UF260
- Forced convection airflow for consistent heat distribution across large loads
- 256-litre chamber for batch processing and high-throughput workflows
- Stable temperature control up to 300°C
- Efficient heating performance even with full chamber loads
- Digital control system for accurate and repeatable settings
- Stainless steel interior designed for durability and easy cleaning
- Adjustable fan system to match different sample requirements
Applications
The Memmert UF260 universal oven is well suited for:
- High-volume laboratory drying
- Batch processing of samples
- Industrial and production-related testing
- Pharmaceutical and chemical workflows
- Quality assurance and material conditioning
Why Choose Memmert Ovens
Memmert equipment is widely used for its:
- Consistent and repeatable performance
- Reliable engineering for long-term use
- Stable temperature control across different load sizes
- Proven results in laboratory and industrial settings
Memmert UN vs UF Series – Key Differences
| Feature |
UN Series |
UF Series |
| Convection Type |
Natural Convection |
Forced Convection |
| Air Circulation |
Passive airflow |
Fan-assisted airflow |
| Temperature Uniformity |
Good |
Excellent |
| Heating Speed |
Moderate |
Faster |
| Temperature Recovery |
Slower |
Faster |
| Noise Level |
Silent |
Slight fan noise |
| Application Suitability |
Basic drying, simple heating |
Precision drying, sensitive applications |
| Energy Consumption |
Lower |
Slightly higher |
| Price Range |
More affordable |
Higher (due to performance) |
Why Work With Copens Scientific?
- Genuine Memmert laboratory equipment
- Expert technical consultation for your applications
- Reliable after-sales support and assistance
- Experience supporting laboratories across Malaysia
- Responsive service for enquiries and quotations
Get Expert Advice or Custom Solutions?
On this page, you’ll find the essential technical details of the Memmert universal oven.
If you need further clarification, our customer support team is ready to assist with product selection, specifications, and application suitability.
For customised solutions or special requirements, feel free to contact our technical specialists at info@copens-sci.com
Technical Specification
Temperature
| Working temperature range |
at least 5 (UN/UNplus/UNm/UNmplus) or 10 (UF/UFplus/UFm/UFmplus) above ambient temperature to +300 °C |
| Setting accuracy temperature |
up to 99.9 °C: 0.1 / from 100 °C: 0.5 |
| Setting temperature range |
+20 to +300 °C |
| Temperature sensor |
1 Pt100 sensor DIN class A in 4-wire-circuit |
Control technology
| ControlCOCKPIT |
SingleDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with high-definition TFT-colour display |
| Timer |
Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
| Function SetpointWAIT |
the process time does not start until the set temperature is reached |
| Calibration |
three freely selectable temperature values |
| adjustable parameters |
temperature (Celsius or Fahrenheit), fan speed, air flap position, programme time, time zones, summertime/wintertime |
Ventilation
| Fan |
forced air circulation by quiet air turbine, adjustable in 10 % steps |
| Fresh air |
Admixture of pre-heated fresh air by electronically adjustable air flap |
| Vent |
vent connection with restrictor flap |
Communication
| Documentation |
programme stored in case of power failure |
| Programming |
AtmoCONTROL software for reading out, managing and organising the data logger via Ethernet interface (temporary trial version can be downloaded). USB stick with AtmoCONTROL software available as accessory (on demand). |
Safety
| Temperature control |
adjustable electronic overtemperature monitor and mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature |
| Autodiagnostic system |
for fault analysis |
Standard equipment
| Works calibration certificate |
Calibration at +160°C |
| Door |
fully insulated stainless steel door with 2-point locking (compression door lock) |
| Internals |
2 stainless steel grid(s), electropolished |
Stainless steel interior
| Dimensions |
w(A) x h(B) x d(C): 640 x 800 x 500 mm (d less 39 mm for fan) |
| Interior |
easy-to-clean interior,made of stainless steel, reinforced by deep drawn ribbing with integrated and protected large-area heating on four sides |
| Volume |
256 l |
| Max. number of internals |
9 |
| Max. loading of chamber |
300 kg |
| Max. loading per internal |
20 kg |
Textured stainless steel casing
| Dimensions |
w(D) x h(E) x d(F): 824 x 1183 x 684 mm (d +56mm door handle) |
| Housing |
rear zinc-plated steel |
Electrical data
Voltage
Electrical load
|
230 V, 50/60 Hz approx. 3400 W |
Ambient conditions
| Set Up |
The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. |
| Altitude of installation |
max. 2,000 m above sea level |
| Ambient temperature |
+5 °C to +40 °C |
| Humidity rh |
max. 80 %, non-condensing |
| Overvoltage category |
II |
| Pollution degree |
2 |
Packing/shipping data
| Transport information |
The appliances must be transported upright |
| Customs tariff number |
8419 8998 |
| Country of origin |
Federal Republic of Germany |
| WEEE-Reg.-No. |
DE 66812464 |
| Dimensions approx incl. carton |
w x h x d: 930 x 1380 x 930 mm |
| Net weight |
approx. 110 kg |
| Gross weight carton |
approx. 161 kg |
Standard units are safety-approved and bear the test marks
×